Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/73841
Title: การศึกษาภาวะแทรกซ้อนเชิงกลที่เกี่ยวข้องกับชนิดของสิ่งบูรณะบนรากฟันเทียมในผู้ป่วยภาควิชาทันตกรรมประดิษฐ์ คณะทันตแพทยศาสตร์ มหาวิทยาลัยเชียงใหม่ : ศึกษาย้อนหลัง 5 ปี
Other Titles: Study of mechanical complication associated with type of implant prostheses in Prosthodontics department, faculty of Dentistry, Chiang Mai university: 5 years retrospective
Authors: กัณฐิกา เข็มทอง
Authors: พิสัยศิษฎ์ ชัยจรีนนท์
กัณฐิกา เข็มทอง
Issue Date: Jun-2022
Publisher: เชียงใหม่ : บัณฑิตวิทยาลัย มหาวิทยาลัยเชียงใหม่
Abstract: Objective: To study the severity of mechanical complications related to dental implants and implant restorations in patients of the Department of Prosthodontics. Faculty of Dentistry, Chiang Mai University Methods: A retrospective study of 53 patients, total 130 implants, whose had been follow-up after treatment from 1 to 5 years. Patients with implants and restorations on implants were: Removable prosthesis (overdentures, removable partial dentures supported by dental implants), Fixed prosthesis (single crown on implant, bridge on implant) from the Department of Prosthodontics. Patients will be examined on a form and recorded complications of the implant and restoration. Results: The result showed that most frequent mechanical complication was minor complication. Loosening of the implant screw and loss of filling material in the screw hole, were 39.2% and 38.5%, respectively. Based on the type of implant restorative, mechanical complication was most common in single crown on implant. Severity of mechanical complication were considered as minor complication, which was 43 implants or 33.0%, While major complication was found 9 teeth, representing 6.9%. Compared with type of restoration, there was no significant difference at P<0.05. Conclusion: Mechanical complications of dental implants and implant restorations in the Department of Prosthodontics Faculty of Dentistry Chiang Mai University, it can be concluded that incidence of abutment screw loosening was the most common in minor complication.
URI: http://cmuir.cmu.ac.th/jspui/handle/6653943832/73841
Appears in Collections:DENT: Theses

Files in This Item:
File Description SizeFormat 
กัณฐิกา 21 กค ลายน้ำ.pdfเล่มวิทยานิพนธ์ การศึกษาภาวะแทรกซ้อนเชิงกลที่เกี่ยวข้องกับชนิดของสิ่งบูรณะบนรากฟันเทียมในผู้ป่วยภาควิชาทันตกรรมประดิษฐ์ คณะทันตแพทยศาสตร์ มหาวิทยาลัยเชียงใหม่ : ศึกษาย้อนหลัง 5 ปี8.63 MBAdobe PDFView/Open    Request a copy


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.