Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/67850
Title: A study on developing ventilation in restaurants in re-purposed row houses
Authors: Sumavalee Chindapol
Authors: Sumavalee Chindapol
Keywords: Environmental Science
Issue Date: 1-Jan-2019
Abstract: © 2019, Chulalongkorn University - Environmental Research Institute. All rights reserved. The building ventilation of seventy-seven row houses in eight districts in Chiang Mai province of Thailand was surveyed and investigated. A typical row house re-purposed as a restaurant refers to a 3.5 m high space with two stoves in the front of the building and a closed rear area to serve as storage. As a base-case, restaurants had an average capacity of 24 customers in the dining area. Measurements of internal air quality of a selected restaurant were conducted in the summer season of 2015 and 2017, and the results revealed average air temperatures of 36°C and 33°C, relative humidity values of 46% and 33%, and air speed values of 0.28 m s-1 and 0.10 m s-1, respectively. The Computerised Fluid Dynamics (CFD) and the Center for the Built Environment (CBE) thermal comfort tool were used to simulate the efficiency of current and proposed ventilation techniques and also analyse thermal comfort conditions for each scenario. Low-cost cooling techniques of air speed and humidity adjustment were chosen to improve thermal conductions. By applying the combined techniques, the overall temperature was reduced by 2°C and the thermal comfort levels were improved from the ‘hot’ to the ‘warm’ zone. Some conditions in the second restaurant are in the expanded ‘adaptive thermal comfort zone’. Although most results appear to exceed the ‘adaptive thermal comfort zone’, conditions could not be further ameliorated since 1.5 m s-1 was the maximum air speed that could be employed in the dining area to avoid wind discomfort. Limited investment in ventilation improvement was the main challenge since air-conditioners and multiple fans were not affordable and were also insufficient for the re-adaptation option. Feasibility study of ventilation improvement technique is limited in this study.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85076725710&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/67850
ISSN: 2287075X
22870741
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.