Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/66642
Title: Comparative study of immediate loading on short dental implants and conventional dental implants in the posterior mandible: A randomized clinical trial
Authors: Kritsada Weerapong
Siripong Sirimongkolwattana
Thanapat Sastraruji
Pathawee Khongkhunthian
Authors: Kritsada Weerapong
Siripong Sirimongkolwattana
Thanapat Sastraruji
Pathawee Khongkhunthian
Keywords: Dentistry
Issue Date: 1-Jan-2019
Abstract: © 2019 by Quintessence Publishing Co Inc. Purpose: Immediate dental implant loading has been investigated with favorable results. However, short implants have not been investigated in this treatment option. This study compared the clinical outcomes and survival rates of immediately loaded short and conventional-length dental implants in replacing mandibular molar teeth. Materials and Methods: Forty-six implants (23 short dental implants and 23 conventional dental implants) in 46 patients were included in the study. Provisional computer-aided design/computeraided manufacturing (CAD/CAM) ceramic crowns were cemented to the abutments and immediately loaded. Several clinical parameters were recorded and statistically analyzed at 4-month and 1-year follow-up. Results: Two short implants lost integration, and one conventional implant failed. No statistically significant difference between the two implant types was found (P = 1.00). Minor complications were recorded; three provisional crown fractures were found in the short implant group and two provisional crown fractures in the conventional implant group. There was no significant difference in implant stability quotient values for short or conventional implants between baseline (short: 73.86 ± 2.38, conventional: 75.05 ± 3.26, P = .088), 4 months after loading (short: 72.37 ± 1.35, conventional: 72.89 ± 1.87, P = .165), and 1 year after loading (short: 74.60 ± 2.03, conventional: 75.35 ± 2.66, P = .296). The mean marginal bone level loss 4 months postloading was 0.28 ± 0.29 mm for short implants and 0.25 ± 0.25 mm for conventional implants (P = .73), and at 1 year postloading was 0.33 ± 0.47 mm for short implants and 0.26 ± 0.27 mm for conventional implants (P = .554); there was no statistical difference between the two implant types. Conclusion: The immediate loading of short implants is comparable to conventional-length implants in terms of implant survival, marginal bone level change, and implant stability quotient value.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85060640176&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/66642
ISSN: 10866019
08822786
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.