Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/61228
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFuanglada Tongpraserten_US
dc.contributor.authorTheera Tongsongen_US
dc.contributor.authorChanane Wanapiraken_US
dc.contributor.authorSupatra Sirichotiyakulen_US
dc.contributor.authorWirawit Piyamongkolen_US
dc.date.accessioned2018-09-10T04:07:03Z-
dc.date.available2018-09-10T04:07:03Z-
dc.date.issued2007-12-01en_US
dc.identifier.issn10970223en_US
dc.identifier.issn01973851en_US
dc.identifier.other2-s2.0-37049024758en_US
dc.identifier.other10.1002/pd.1836en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=37049024758&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/61228-
dc.description.abstractObjective: To describe the experiences in diagnostic cordocentesis in twin pregnancies at midpregnancy Methods: The database and medical records of pregnant women attending Maternal Fetal Medicine Unit of the hospital for diagnostic cordocentesis at midpregnancy between January 1989 and September 2006 were retrospectively reviewed. Results: During 17 years of experience, 4241 cordocenteses at midpregnancy were performed for prenatal diagnosis, including 59 procedures in 30 multiple pregnancies (29 twins and 1 triplet). The mean gestational age at the time of cordocentesis was 19.5 ± 1.6 weeks. Success rate of the samplings was 98.3% with one sample was maternal blood contamination. Averaged-time used of the procedures was 8.2 minutes (range 1-45 minutes). The procedure-related complications included transient bleeding at puncture site (8.5%) and transient fetal bradycardia (22.0%). The total fetal loss rate was 10.5% but there was no cordocentesis-related fetal loss (0.0%), defined as a fetal loss within 2 weeks after the procedure. Conclusion: This study may provide a new insight on the safety of cordocentesis in multifetal pregnancies at midpregnancy. The procedure-related fetal loss is not as high as reported in the past. This study suggests cordocentesis be a relatively safe and highly successful in obtaining fetal blood samples. Copyright © 2007 John Wiley & Sons, Ltd.en_US
dc.subjectMedicineen_US
dc.titleCordocentesis in multifetal pregnanciesen_US
dc.typeJournalen_US
article.title.sourcetitlePrenatal Diagnosisen_US
article.volume27en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.