Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/57409
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWannapha Nobnopen_US
dc.contributor.authorHudsaleark Neaminen_US
dc.contributor.authorImjai Chitapanaruxen_US
dc.contributor.authorSomsak Wanwilairaten_US
dc.contributor.authorVicharn Lorvidhayaen_US
dc.contributor.authorTaweap Sanghangthumen_US
dc.date.accessioned2018-09-05T03:40:52Z-
dc.date.available2018-09-05T03:40:52Z-
dc.date.issued2017-12-01en_US
dc.identifier.issn20513909en_US
dc.identifier.issn20513895en_US
dc.identifier.other2-s2.0-85026485978en_US
dc.identifier.other10.1002/jmrs.236en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85026485978&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/57409-
dc.description.abstract© 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology Introduction: The application of deformable image registration (DIR) to megavoltage computed tomography (MVCT) images benefits adaptive radiotherapy. This study aims to quantify the accuracy of DIR for MVCT images when using different deformation methods assessed in a cubic phantom and nasopharyngeal carcinoma (NPC) patients. Methods: In the control studies, the DIR accuracy in air-tissue and tissue-tissue interface areas was observed using twelve shapes of acrylic and tissue-equivalent material inserted in the phantom. In the clinical studies, the 1st and 20th fraction MVCT images of seven NPC patients were used to evaluate application of DIR. The eight DIR methods used in the DIRART software varied in (i) transformation framework (asymmetric or symmetric), (ii) DIR registration algorithm (Demons or Optical Flow) and (iii) mapping direction (forward or backward). The accuracy of the methods was compared using an intensity-based criterion (correlation coefficient, CC) and volume-based criterion (Dice's similarity coefficient, DSC). Results: The asymmetric transformation with Optical Flow showed the best performance for air-tissue interface areas, with a mean CC and DSC of 0.97 ± 0.03 and 0.79 ± 0.11 respectively. The symmetric transformation with Optical Flow showed good agreement for tissue-tissue interface areas with a CC of (0.99 ± 0.01) and DSC of (0.89 ± 0.03). The sequences of target domains were significantly different in tissue-tissue interface areas. Conclusions: The deformation method and interface area affected the accuracy of DIR. The validation techniques showed satisfactory volume matching of greater than 0.7 with DSC analysis. The methods can yield acceptable results for clinical applications.en_US
dc.subjectHealth Professionsen_US
dc.subjectMedicineen_US
dc.titleAccuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) imagesen_US
dc.typeJournalen_US
article.title.sourcetitleJournal of Medical Radiation Sciencesen_US
article.volume64en_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsChulalongkorn Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.